Ferroli GN2 N and GN4 N: cast-iron boilers for large systems – and the last units in stock

Ferroli’s GN series are the large cast-iron boilers for oil and gas forced-draught burners in residential blocks, institutions and commercial buildings. Here are the technical key figures for GN2 N and GN4 N, what you need to know about the replacement rules – and why now is the time to act if you have a system that needs a new boiler.

GN2 N: 87–252 kW in a compact package

GN2 N is a floor-standing cast-iron boiler with partial flame reversal and one flue pass, designed for oil and/or gas forced-draught burners.

  • Output: from 87–107 kW (GN2 N 06) up to 199–252 kW (GN2 N 14)
  • Boiler body: G20 cast iron with 6–14 sections, factory pre-assembled with steel cone inserts and studs
  • Insulation: rock wool with tear-proof lining
  • Operating pressure: max. 6 bar
  • Connections: flow and return DN80 (3″), drain 3/4″
  • Dimensions: 600 mm wide and 1196 mm high in all sizes. Only the depth grows with the number of sections (757–1637 mm).
  • Low flue-side resistance: 0.4 mbar in the combustion chamber on all sizes
  • Control panel: thermo-hydrometer, safety thermostat, 2-stage control thermostat, main switch, burner lockout indicator and space for an electronic controller
  • Ready for 2-stage burners

The boiler is delivered in three packages: boiler body in a wooden crate, jacket and instrument panel in separate boxes. The narrow 600 mm width makes the GN2 N easy to get through a standard boiler-room door.

GN4 N: 120–650 kW with three flue passes

GN4 N is the big brother with three flue passes and a cooled combustion chamber, for the really large systems.

  • Output: from 120–200 kW (GN4 N 07) up to 390–650 kW (GN4 N 14)
  • Efficiency: up to approx. 97 % at 30 % load and 92–93 % at full load
  • Low-temperature operation: suitable for traditional systems or low-temperature systems with a minimum return temperature of 35 °C
  • Sectional design: the boiler body is assembled in the boiler room, so even the largest sizes can be brought in through narrow access routes. Ferroli offers a dedicated section assembly tool.
  • Operating pressure: max. 6 bar
  • Connections: flow and return DN80 (3″) plus separate DN80 connections for a low-temperature circuit
  • Width and height: 850 × 1193 mm, depth 1040–1950 mm
  • Ready for 2-stage burners, with space for a flue gas thermostat and electronic controller

Important: replacement of the same model

Under the EU ecodesign rules (Regulation 812/2013), the GN2 N and the smallest GN4 N sizes (07–10) may only be sold in the EU as a replacement of an identical model. This means:

  • If a customer has a GN2 N or GN4 N that is worn out, it can be replaced with the same boiler – same dimensions, same connections and same burner set-up.
  • It saves time in the boiler room: no re-piping, no new base adaptation and no new access routes.
  • In many cases the existing burner can be reused if it is in good condition.

Always check the rating plate on the old boiler before ordering.

Remaining stock: only a few units left